Skip to main content
Texsa Waterproofing Systems
Injection & Repair

Structural Crack Injection UAE

Epoxy injection to restore monolithic concrete integrity.

Structural crack injection bonds a dormant crack back into monolithic concrete using a low-viscosity structural epoxy. Surface ports are set, the crack face is sealed, and resin is injected under controlled pressure until it travels through the full depth of the section.

Service line
Injection & Repair
Region
UAE
Lead time
On request

Overview

Low-viscosity structural epoxy is injected under pressure through surface packers to fill and bond dormant cracks in concrete — restoring load-transfer capacity and creating a permanent monolithic repair.

Systems & specifications

Key advantages

  • Low-viscosity structural epoxy resins

  • Surface and drilled-port packer installation

  • Pressure-controlled single and twin-pump injection

  • Crack width 0.1 mm and above

  • Documented injection logs per crack

How we execute

Engineering capability

Surface compatibility

    QA / QC procedure

      Equipment capability

        Our diagnostic process

        We find the root cause before we quote.

        Every repair starts with a structured site investigation — so the fix is permanent, not cosmetic.

        • 01
          Crack mapping & width measurement
        • 02
          Moisture and chloride testing
        • 03
          Concrete cover & rebar scan (GPR)
        • 04
          Hydrostatic head assessment
        • 05
          Resin selection per crack movement
        Repair methods

        The right technique, not a one-size repair.

        01

        Epoxy resin injection

        Low-viscosity epoxy structurally welds dormant cracks under controlled pressure, restoring load transfer.

        02

        Polyurethane resin injection

        Hydrophobic or hydrophilic PU resins seal active, water-bearing cracks by foaming on contact with moisture.

        03

        Hybrid two-stage injection

        PU foam first stops the leak, followed by epoxy for permanent structural sealing.

        Emergency response
        Site survey within 24 hours across UAE — crews mobilised the same week.
        Call us for structural crack injection

        Evidence from site

        Typical applications

        Where structural crack injection delivers value across UAE infrastructure, industrial and commercial assets.

        • General

          Structural slabs, beams, and columns

        • General

          Shear walls and retaining structures

        • Building

          Bridge decks and infrastructure repairs

        • Civil

          Industrial floors and foundations

        Sectors served

        InfrastructureTunnels & MetroCommercialIndustrialWater Sector
        Frequently asked

        Structural Crack Injection — answered.

        Common questions from UAE consultants, clients and contractors. Need something specific? Speak with our technical team.

        Epoxy is used when the crack is dormant and the repair must transfer load across the section. PU is used when the crack still moves or is actively leaking, because cured epoxy is rigid.
        Speak with our technical team

        Specify Structural Crack Injection on your next project.

        Share your project details and requirements, and our team will get in touch to discuss the most suitable solution.

        View projects
        CallWhatsApp